LS Mecapion Servo Drive APD-VS20N
Kami menjual Produk LS Mecapion Servo Drive APD-VS20N Yang Berkualitas Original Dengan harga yang bersaing Kebutuhan anda Kami Solusinya:
The LS Mecapion APD-VS20N is a 2.0kW (2000W) AC servo drive, serving as one of the most powerful units in the APD-VS product line. Designed for high-inertia loads and heavy-duty industrial machinery, it provides the necessary torque for applications like industrial milling, heavy-duty conveyors, and large-scale automation systems.
Technical Specifications
The “20” in the model name signifies its 2.0kW output capacity. This drive requires a robust power infrastructure to handle the high current draws during peak operation.
Rated Output: 2.0kW (2000W).
Input Voltage: 3-Phase AC 200V ~ 230V (50/60Hz).
Rated Current: Approximately 12.0A – 13.0A.
Maximum Current (Peak): Up to 300% of rated current for short-duration acceleration.
Encoder Support: Typically paired with Incremental Encoders (2048/2500/3000 PPR) via the CN2 port.
Cooling: Forced air cooling with high-capacity internal fans.
Comparison: APD-VS15N vs. APD-VS20N
The VS20N shares the same physical series characteristics as the VS15N but has a reinforced power stage to deliver higher continuous current.
| Feature | APD-VS15N | APD-VS20N |
| Power Output | 1.5kW | 2.0kW |
| Rated Current | ~9.5A | ~12.5A |
| Cooling | Forced Air Fan | Forced Air Fan |
| Standard Motor | APM-S15A | APM-S20A / APM-SC20A |
Key Installation Requirements
External Braking Resistor: Due to the 2.0kW power level, this drive generates significant regenerative energy when stopping heavy loads. Connecting an external regenerative resistor to terminals B1 and B2 is essential for most 2kW setups to prevent AL-04 (Overvoltage) errors.
Three-Phase Power: While smaller VS drives might tolerate single-phase input with derating, the VS20N strictly requires a 3-phase 200-230V supply to maintain stable torque and protect the internal diode bridge from overheating.
Wiring (CN1): Uses the standard 50-pin control signal connector for Pulse/Direction inputs and digital I/O.
Troubleshooting & Status
Legacy Lifecycle: Like the rest of the VS series, the APD-VS20N is a legacy model. It has been superseded by the LS Electric L7 Series (modern equivalent: L7SA020B).
Common Faults: * AL-05 (Overload): Often seen if the load inertia is set incorrectly or if there is a mechanical binding in the system.
AL-01 (Overcurrent): Can indicate a short in the motor power cable or a failure in the drive’s IGBT module.
Software: Configuration is handled via the Mecapion PC Loader software. For a 2.0kW unit, ensuring the Inertia Ratio (parameter-based) is accurately tuned is critical to prevent mechanical oscillation.
APD-VS370N
APD-VS300N
APD-VS220N
APD-VS150N
APD-VS110N
APD-VS75N
APD- VS50N
APD-VS35N
APD-VS20N
APD-VS15N
APD-VS10N
APD-VS05N
APD-VS04N
APD-VS02N
APD-VS01N
APD-VSR5N
Pesan Sekarang! Silahkan Hubungi Untuk informasi lebih jelas Sales Marketing kami
PT Adinata Jaya Teknik
Alamat: 18 OFFICE PARK BUILDING 12Th Floor Unit E
JL TB Simatupang No.18 RT 002 RW 001
KEL. Kebagusan KEC. Pasar Minggu
Jakarta Selatan
Telepon: 021 2127 5727
Email: info@adinatajayateknik.com